General information | |
---|---|
Origin | Brand : Japan - Manufacture of : Thailand |
Gas | R-32 |
Type | Inverter (save energy) |
Cooling capacity | 6.0 Hp ~ 51.000 Btu/h |
Using for rooms | Area 77 - 80 m² or 231 - 240 m³ (suitable for living room, office) |
Power source (Ph/V/Hz) | 3 Phase 380 - 415 V 50Hz |
Electricity consumption | 5,71 Kw |
Refrigerant/ Liquid Pipe Diameter (mm) | 9.5 / 15.9 |
Maximum Pipe Length (m) | 50 (m) |
Maximum Elevation Length (m) | 30 (m) |
Cooling Seasonal Performance Factor (CSPF) | 4.18 |
In door unit | |
Model Name | FVA140AMVM |
Dimensions (H x W x D) (mm) | 1.850 x 600 x 350 (mm) |
Weight (Mass) (Kg) | 50 (kg) |
Outdoor Unit | |
Model Name | RZF140CYM |
Dimensions (H x W x D) (mm) | 990 x 940 x 320 (mm) |
Weight (Mass) (Kg) | 64 (kg) |
Inverter Cooling One Way
Specially designed for shops, restaurants, and small offices, the SkyAir inverter series meets all customer needs thanks to the variety of indoor units and power supplies.
- Inverter technology.
- Diverse indoor units.
- Outdoor heat sink fins are treating against corrosion.
- Easy-to-use remote navigation control, Weekly Schedule feature.
Floor Standing indoor unit
New airflow control for more comfort
- Auto swing direction is selectable from 3 patterns to suit the layout to room (Swing wide across the front, Swing across the left side, Swing across right side) to match the room structure (Applicable when BRC1E62 use). Up and down directions Independent up-and-down airflow directions facilitate even room temperature and help save energy (by hand).
- DC fan motor improves efficiency.
- Quite Operation.
- Easy Installation and easy maintenance.
- Switchable fan speed.
New airflow control for more comfort
Auto swing direction is selectable from 3 patterns to suit the layout of the room.
Up and down directions: Independent up-and-down airflow directions facilitate even room temperature and help save energy
Comfortable Airflow Control
Switchable fan speed: 3 steps and Auto.
High fan speed mode
To carry airflow to the far side of the room, airflow rate can be increased 5% or 10% depending on the installation condition or customer's request. (Field setting by remote controller). (applicable for FVA50-100)
Programme "Dry". Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Quite Operation
Inverter technology high CSPF
Thanks to the combination of energy-saving technologies, the product's CSPF achieves between 4.85 and 6.47.
Outdoor unit compact, save space
Compared with the previous non-inverter model, the new outdoor unit is more compact with a height of only 990mm. Easy to install in confined spaces, while maintaining a high CSPF energy-saving performance.
Heat exchange fins are provided with anti-corrosion treatment
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, Anti corrosion treated fin for heat exchangers (pretreated with acryl) are used for the heat exchanger of the outdoor unit.
Easy-to-use navigation remote with Weekly Schedule feature
Faster cooling and dehumidification: New inverter control technology brings quick comfort. (One-way)
Quick cooling start function: Quickly and easily make space comfortable before the arrival of office workers or shop customers. As well as quick cooling at maximum capacity, new inverter control rapidly removes indoor humidity. More than simple temperature reduction, this twin reduction provides greater comfort (within a maximum
of 30 minutes).
Why is inverter technology economical?
Inverter system consumes less electricity, and soon recovers the difference in initial cost. This results in lower total cost.
Inverter air conditioner can adjust its cooling capacity according to the cooling load. This results in less power consumption.
In response to fluctuating cooling load, Non inverter air conditioners repeatedly perform ON (full-power) / OFF (zero-power) operation. Inverter air conditioners, however, operate at optimal cooling capacity according to the cooling load. Since inverter air conditioners provide required minimum cooling capacity with minimum electrical power, total power consumption can be reduced during cooling period.
Why is inverter technology more comfortable?
When temperature does not fluctuate much, the set temperature is maintained. Inverter control responds to load changes and causes minor temperature adjustments. Non-inverter control frequently turns ON and OFF in response to load fluctuations or load mismatch and causes large temperature swings.
Other convenient functions: Better still,... Advanced Daikin inverter technology brings many different benefits to customers and installers.
Automatic protection against low voltage: In AM and PM peak electricity consumption periods, supply may fluctuate. Built-in low-voltage protection will automatically cut operations. When normal voltage is restored, operation will resume as before.
Coated printed circuit boards: Coated circuit boards prevent problems caused by humidity and airborne dust. It also protects against salt contained in sea breezes. Both sides of the PCB in outdoor units are coated.
Self-diagnosis functions enable prompt maintenance response: An error message appears on the LCD of the remote controller and an LED lights up on the unit. When the BRC1E62 is installed, the error code appears showing contact information and model name. Contact your Daikin dealer and provide the error code and model name.
The BRC1E62 remote controller includes convenient functions
Setpoint auto reset
- Even if the set temperature is changed, the new set temperature returns to the previous preset value after a preset duration of time.
- Period selectable from 30, 60, 90, or 120 min.
Setpoint range set
- Saves energy by limiting the min. and max. set temperature.
- Avoids excessive heating or cooling.
- This function is convenient if the remote controller is installed where anyone can change the settings.
Night quiet operation mode
Consideration is given for people living nearby. Outdoor unit operating sound can be reduced.
Technology
Advanced technology, including the use of corrosion resistant electronic expansion valves, acid neutralisers and improved compressor reliability, enables the re-use of existing piping* without the need of pipe flushing for a simplified replacement process.
Note:
- Rated cooling capacities are base on the following conditions: Room temperature 27 ° CDB, 19 ° CWB; outdoor temperature 35 ° CDB, 24 ° CWB; 7.5 m equivalent refrigerant piping (horizontal)
- Capacity is net value, including the deduction of heat from an indoor engine.
- Value converted under anechoic chamber conditions. If measured under actual installation conditions, the actual value is usually higher than the specification due to ambient noise and acoustical echo.