General information | |
---|---|
Origin | Brand : Japan - Manufacture of : Thailand |
Gas | R-410A |
Type | Non-Inverter Air Conditioner (Mono) |
Cooling capacity | 18.0 Hp ~ 180.000 Btu/h |
Using for rooms | Area 235 - 240 m² or 705 - 720 m³ (suitable for living room, office) |
Power source (Ph/V/Hz) | 3 Phase 380 - 415 V 50Hz |
Electricity consumption | 21,2 kW |
Refrigerant/ Liquid Pipe Diameter (mm) | 15.9 / 34.9 |
Maximum Pipe Length (m) | 50 (m) |
Maximum Elevation Length (m) | 30 (m) |
In door unit | |
Model Name | FVPGR18NY1 |
Dimensions (H x W x D) (mm) | 1.870 x 1.470 x 720 (mm) |
Weight (Mass) (Kg) | 240 (kg) |
Outdoor Unit | |
Model Name | RUR18NY1 |
Dimensions (H x W x D) (mm) | 1.680 x 1.240 x 765 (mm) |
Weight (Mass) (Kg) | 322 (kg) |
Dimensions (unit: mm)
Floor standing indoor unit - Duct connection type
Floor standing outdoor unit - Duct connection type
Design flexibility
Designed for long refrigerant piping
50 m maximum length and 30 m maximum level difference to cover medium- and large-scale building needs.
Space savings
Installation space is saved thanks to a more compact outdoor unit. This also makes it easier to install.
Energy saving
Using state-of-the-art heat pump technology increases efficiency and reduces power consumption, considerably save your business monthly electricity costs.
Air blow via connected ducts
Comfortable air conditioning of the entire factory by connecting a blow duct at the top of the indoor unit.
Enhanced varieties of factory modification and optional accesories
Note:
- Wiring modification is needed on floor stand model to connect with central control ADP kit.
- Need to use central control adapter kit for option connection.
- Central control adapter kit and LCD remote controller is necessary for option connection.
Diverse solution
Daikin offers diverse solutions for applications requiring high precision in temperature control and air quality.
Refrigerant pre charged for up to 7.5 metres
4-direction piping affords more freedom of layout
Piping can be run from the front, bottom, right or rear surface according to how the unit is installed.
Note: Additional refrigerant charging is required if the refrigerant pipe is longer than the indicated length.
Quiet operation
Equipped with scroll compressor for quiet operation
Smooth running, low vibration, low operating sound.
Durability
Heat exchange fins provided with anti-corrosion treatment
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
Fresh air intake mode
- Fresh air intake mode use as the air conditioner for outdoor air handling.
- Some restrictions arise when using the appliance as an outdoor air handling unit. Strictly comply with the provisions of the Technical Documentation.
- Duct connection type: Duct connection allows for uniform air conditioning in large spaces.
- Note that the noise increases by approximately 5 dB (A).
Easy maintenance
Designed with high serviceability to allow repair and maintenance services performed in front of the machine.
Fan Performance
Wiring and Piping
Space required for indoor unit installation (Unit:mm)
Space required for outdoor unit installation (unit:mm)
Note
1. Height of wall according to models 1 and 2. Front: 1500mm. Suction side: 500mm. Side: no height restriction. The installation space depicted in the figure above is base on a refrigeration standard with an outdoor temperature of 35 ° C .
2. When the outside design temperature exceeds 35 ° C or is likely to exceed the limit due to the heat radiating from the outdoor units, the outdoor unit return space should enlarge larger than the required dimension bridge in figure .
3. During equipment installation, it is advisable to follow the distance and space regulations in the figure below to maintain enough space for the device to operate and for future maintenance. The unit should install in such a location that the space in front of the appliance is large enough for the connection solvent pipe and convenient for disassembly.
Specifications
Note:
• Rated cooling capacity is base on the following conditions: return wind temperature 27 ° CDB, 19.5 ° CWB, outdoor temp .: 35 ° CDB. Equivalent gas pipe length 5m.
• Sound level is measure under conditions in soundproof rooms, according to JIS standards and parameters. During operation, this value may be higher due to ambient conditions.
• Productivity includes indoor fan heat.