General information | |
---|---|
Origin | Brand : Japan - Manufacture of : Thailand |
Gas | R-410A |
Type | Inverter (save energy) |
Cooling capacity | 6.0 Hp ~ 51.000 Btu/h |
Heating capacity | 14.0 ( 4.0 ~ 16.0 ) kW |
Using for rooms | Area 77 - 80 m² or 231 - 240 m³ (suitable for living room, office) |
Power source (Ph/V/Hz) | 3 Phase 380 V 50Hz |
Electricity consumption | 4.36 / 3.69 (kW) |
Refrigerant/ Liquid Pipe Diameter (mm) | 9.52(3/8”) / 15.88(5/8”) mm |
Maximum Pipe Length (m) | 50 m |
Maximum Elevation Length (m) | 50/15 m |
Energy Label | 5 stars |
In door unit | |
Dimensions (H x W x D) (mm) | 280 x 1,370 x 740 mm |
Weight (Mass) (Kg) | 54 kg |
Outdoor Unit | |
Dimensions (H x W x D) (mm) | 845 x 970 x 370 mm |
Weight (Mass) (Kg) | 82 kg |
Slim design and completely hidden under the ceiling for a luxurious beauty
Mitsubishi Heavy duct connected inverter air conditioning FDUM125VF/FDC125VSA (12.5kW) - 3 phase - Low/Middle Static pressure has a thin design. The height of all FDUM models is only 280mm, this product has many advanced designs that bring the most comfort and convenience to users. Using the inverter system to save electricity, the inverter and the R410A Refrigerant line are environmentally safe.
High Efficiency cooling / heating capacity
A 2-way air conditioning with 12.5 kW cooling capacity and a 14.0 kW heating capacity for a room area of 64 - 67 m2 for optimum performance is the Mitsubishi Heavy duct connected air conditioning FDUM125VF/FDC125VSA inverter (6.0Hp) - 3 phase. The machine uses 380-415V, 50Hz / 380V, 60Hz 3-phase power source.
Automatic External Static Pressure (E.S.P.) Control
Mitsubishi Heavy duct connected air conditioning FDUM125VF/FDC125VSA inverter (6.0Hp) - 3 phase can set required E.S.P by E.S.P. button in the wired remote controller.
New advanced technology of MHI has expanded the heating and cooling operation range
This permits installation of the units under a low outdoor temperature conditions down to -15˚C/-20˚C In heating operation and -15˚C in cooling operation.
Micro Inverter technology saves electricity
Seer & SCOP high efficiency
Reduced size and increased efficiency due to the use of a DC twin rotary compressors one-way (4-6HP type)
Adoption of DC twin rotary compressor has enabled to utilize a high-speed range of up to 120 rps at the maximum to secure the required capacity.Optimum compressor control has been realized by employing the vector control* and the starting current has been improved significantly compared with former models. Moreover, vibration has been reduced.
Vector control means a technique to realize an optimum control by converting the current wave to a smooth sinusoidal waveform.
Long piping
* When the outdoor unit is installed at a position higher than the indoor unit by 30m or more, set SW5-2 on the control PCB to ON.
Quite operation
Set the length of time the component operates with a low noise priority.
Improvement of the Serviceability
Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance can be carried out from the right side or the bottom side of the unit.
Enhanced Installation Workability
600mm Drain Pump is mounted in all models. The indoor unit is completely hidden in the ceiling, so this is suitable for spaces with classy interior decoration.
Transparent Inspection Window
Dirt condition of the bottom of a drain pan can be checked through this transparent inspection window without removing drain pan.
Specifications
Powerful-Hi mode selected
Noise level: 100VN (S) AVF2 44dB (A), 125VN (S) AVF 45dB (A), 140VN (S) AVF 47dB (A), 100VN (S) APVF 37dB (A), 125VNAPVF 36dB (A), 140VNAPVF1 38dB (A), 140VNATVF 37dB (A)
Air flow: 100VN (S) VF2 36m3 / min, 125VN (S) VF 39m3 / min, 140VN (S) VF 48m3 / min, 100VN (S) PVF 13m3 / min, 125VNPVF 20m3 / min, 140VNPVF1 24m3 / min, 140VNTVF 13m3 / min
Note:
Parameters measured under conditions (IOS-T1)
Cooling: Room temperature 27˚CDB, 19˚CWB, and outdoor temperature. by 35˚CDB. Heating: Room temperature 20˚CDB and outdoor temp 7˚CDB, 6˚CWB.
* Index obtained in the laboratory. During operation, these readings will vary more due to surrounding environmental conditions
** Indicators only apply when operating one indoor unit
*** Static pressure can change by setting on the controller. The maximum static pressure is set to "High Static Pressure". The noise value will be higher than 5dB (A) when the static pressure level is outside 200Pa
**** If a refrigeration operation performs when the temperature outside is -5oC or below, the outdoor unit must install in a place not affected by natural wind. If the wind blows, the pressure is lowslip and the frequency of the compressor will increase, reduces capacity, and can lead to machine damage.